Experimental

RFC 3954 - Cisco Systems NetFlow Services Export Version 9

Every requirement this repository extracted from RFC 3954, the tests bound to it, and what a reader has verified about them. This summary is enrolled and gated by ./le rfc check.

Overview

Positive

what Ze has

Tested both ways14.3%2 of 14 gated MUSTs

a positive test proves Ze does what the requirement demands and a negative one proves it refuses what the requirement forbids

One polarity plus reason14.3%2 of 14 gated MUSTs

the requirement admits no counter-case, so one polarity plus a recorded reason is the whole proof available for it

One polarity, unexcused0.0%0 of 14 gated MUSTs

one direction is tested, the other is neither tested nor excused, and nothing states which

Partial proof; remaining gap0.0%0 of 14 gated MUSTs

scoped tests exist; the remaining obligation is unmet or unproven, with zero whole-requirement credit

Proven by a recorded break100.0%18 of 18 tagged units

a red was observed once under a recorded procedure, and the unit, the claim and the producer it rested on still hash to what was recorded. The break is not re-run. A test pair is not a proof until one has been observed

Neutral

measures that are neither good news nor bad

Gated MUSTs14of 26 this summary declares

MUST-level requirements the gate HOLDS. A population, not a result: the shares beside it are what says how Ze stands

Out of scope9of 14 gated MUSTs

an obligation that does not bind Ze. A {not-applicable} annotation says it never bound; a {feature-declined} annotation says its condition is an optional feature Ze does not offer, and quotes the RFC sentence that makes it optional. Scope, not coverage: it stays in the denominator every share on this page is taken over

Not applicable64.3%9 of 14 gated MUSTs

a {not-applicable} annotation says the obligation does not bind Ze, so no test is owed for it. It stays in the denominator every share here is taken over

Met below Ze0.0%0 of 14 gated MUSTs

a {lower-layer} annotation says a layer under Ze performs the behavior, on state Ze installs into that layer, and names the producer that installs it. The obligation binds Ze and is met; Ze proves none of it, because its own boundary carries no value the behavior reads

Optional feature declined0.0%0 of 14 gated MUSTs

a {feature-declined} annotation says the obligation is conditional on a feature the RFC makes optional and Ze does not offer, and it quotes the sentence that makes it optional. The condition is false, so nothing is owed and nothing is missing. It stays in the denominator every share here is taken over

Negative

what Ze owes

No test at all7.1%1 of 14 gated MUSTs

no test carries the requirement id, whether or not a gap states why

The 8 shares marked as a part above are the whole of the 14 gated MUSTs: they add to 100%. Proven by a recorded break is a share of TAGGED UNITS, a different population, so it is not one of them.

How to read the colors

A color names what the measure MEANS, not how well Ze scores on it. Green is a good outcome at any value, red is a bad one, and neither a population nor a scope count is an outcome, so both take no color. The number under the label is what says how far Ze has got.

CardTone hereWhy that color
Gated MUSTs neutral no color: a population is a scale, and a larger one is neither good news nor bad. It is the accounting total
Out of scope neutral no color: an obligation that never bound Ze is neither an achievement nor a failure, and counting it either way would be a claim
Tested both ways ok green at every value: a test pair is the outcome this gate exists to produce, and the share under the label is what says how far Ze has got
One polarity plus reason ok green at every value: where no counter-case exists, one polarity IS the complete answer, and a recorded reason is what the gate demands beside it
One polarity, unexcused ok green at zero, RED above it: half a proof with no reason for the other half
Partial proof; remaining gap ok green at zero, RED above it: a tested clause cannot prove the whole requirement
No test at all bad green at zero, RED above it: a binding obligation nothing exercises is a claim with nothing behind it, whether or not a reason is stated
Not applicable neutral no color: an obligation that never bound Ze is neither an achievement nor a failure, and counting it either way would be a claim
Met below Ze neutral no color: an obligation met below Ze is neither a test Ze wrote nor work Ze owes, and the two green shares above are what says how much Ze proves itself
Optional feature declined neutral no color: an obligation whose condition Ze never meets is neither an achievement nor a failure. The absent FEATURE is disclosed on the RFC's own status row, as an implementation gap a later scope decision can revisit
Proven by a recorded break ok green at every value: an observed break is the outcome the discrimination gate exists to produce. The denominator is TAGGED UNITS, not obligations, so this share is not one of the parts above
Audit verdicts warn RED on the first weak, wrong or unimplemented verdict, amber while a verdict is no longer current or a gated MUST is unjudged, green when every one is judged sound and current

At a glance

FieldValue
Public status Experimental
Enrolment Enrolled
Requirements 26
Gated MUST-level 14
Not applicable, so out of scope 9
Declared gaps 1
Declared gaps a test demonstrates 0
Gated with no test 0
Nightly-only evidence 0
Test tags 18
Tagged units 18
Recorded audit verdicts 4
Discrimination records 18
Summary rfc/short/rfc3954.md
Requirement shard rfc/requirements/rfc3954.md
RFC text rfc/full/rfc3954.txt

Enrolment

Enrolled: NetFlow Services Export Version 9 (ze as a v9 exporter): fourteen MUST-level requirements. Four are met: x-1 (never send a Data FlowSet before its Template) and x-8 (the sequence number is cumulative per observation domain) carry positive+negative tags; x-3 (network byte order) and x-9 (a Template ID is constant for the process lifetime) are {single-polarity: positive}. x-2 (refresh templates on both a time interval and a packet-count interval) is {gap}: ze refreshes on a configurable time interval only, with no packet-count-based interval. x-4, x-5, x-6, x-7 are {not-applicable}: they are NetFlow v9 collector requirements and ze is an exporter only. x-22, x-23, x-24, x-25 and x-26 were added by the 2026-09-21 extraction walk from RFC 3954 sections 7 and 9: they are v9 collector obligations (store the Template Record, do not assume Template ID uniqueness across Observation Domains, do not assume Template and Data travel together, do not assume a single Template FlowSet per packet, do not decode with an expired Template) and they are {not-applicable} for the same reason as x-4 to x-7. Disclosed in the docs/features/rfc-status.md RFC 3954 row.

What the public ledger says

Status: Experimental

What the ledger says is covered
  • Flow export templates and records over UDP (exporter): no Data FlowSet before its Template, cumulative per-observation-domain sequence numbers, network byte order, constant Template IDs
  • tests bound per requirement in rfc/requirements/rfc3954.md.
What the ledger says remains Template refresh is time-interval-based only, with no packet-count-based refresh interval (RFC3954-x-2 gap). ze is an exporter only, so the v9 collector requirements x-4 to x-7 are marked not applicable and the five collector obligations added on 2026-09-21 (x-22 to x-26) are marked not applicable too.

Coverage

BucketCountWhat it counts
Positive and negative tests 2 one part of the gated population
Annotated (including scoped evidence) 12 one part of the gated population
One polarity only 0 one part of the gated population
No test and no annotation 0 one part of the gated population
Partial proof; remaining gap (subset of annotated; zero whole-requirement credit) 0 an overlay: each of these is also counted by the part it falls in
Evidence that runs nightly only 0 an overlay: each of these is also counted by the part it falls in
Derived from other rows 0 outside the gated population: each asserts nothing and derives its state from the rows it names, which the parts above already count
Gated MUST-level requirements14every gated MUST falls in exactly one bucket above

Positive and negative tests (2): RFC3954-x-1, RFC3954-x-8

Annotated (including scoped evidence) (12): RFC3954-x-2, RFC3954-x-3, RFC3954-x-4, RFC3954-x-5, RFC3954-x-6, RFC3954-x-7, RFC3954-x-9, RFC3954-x-22, RFC3954-x-23, RFC3954-x-24, RFC3954-x-25, RFC3954-x-26

Requirements

RequirementLevelSectionTests
RFC3954-x-1After a NetFlow process restarts, the Exporter MUST NOT send any Data FlowSet without sending the corresponding Template FlowSet and the required Options Template FlowSet in a previous packet or including it in the same Export Packet. (§7)
MUST NOT 7
RFC3954-x-2On a regular basis, the Exporter MUST send all the Template Records and Options Template Records to refresh the Collector. Template IDs have a limited lifetime at the Collector and MUST be periodically refreshed. Two approaches are taken to make sure that Templates get refreshed at the Collector: * Every N number of Export Packets. * On a time basis, so every N number of minutes. Both options MUST be configurable by the user on the Exporter. (§7)
MUST 7
positiveno testno positive test
negativeno testno negative test

{gap}: ze refreshes NetFlow v9 templates on a time interval only (internal/plugins/flowexport/exporter.go:192-199, config template-refresh seconds); it has no packet-count-based template-refresh interval, so the conjoined time-and-packet-count refresh requirement is only partly met

RFC3954-x-3The Exporter MUST code all binary integers of the Packet Header and the different FlowSets in network byte order (also known as the big-endian byte ordering). (§4)
MUST 4
positiveunit/verifyTestNetflow9DataFlowSet
positiveunit/verifyTestNetflow9Header
positiveunit/verifyTestRFC3954FlowTailBigEndian
negativeno testno negative test

{single-polarity}: ze only ENCODES NetFlow v9 (exporter-only, internal/plugins/flowexport/netflow9); every multi-octet field is written big-endian via binary.BigEndian and there is no decode or wrong-endianness code path to reject, so only the positive can be tested

RFC3954-x-4The Collector MUST use the FlowSet ID to find the corresponding Template Record and decode the Flow Records from the FlowSet. (§5.3)
MUST 5.3
positiveno testno positive test
negativeno testno negative test

{not-applicable}: this is a NetFlow v9 collector requirement (map a Data FlowSet ID to its template); ze is a v9 exporter only (internal/plugins/flowexport/netflow9) with no v9 decode/collect code path

RFC3954-x-5Because an individual Template FlowSet MAY contain multiple Template Records, the Length value MUST be used to determine the position of the next FlowSet record, which could be any type of FlowSet. (§5.2)
MUST 5.2
positiveno testno positive test
negativeno testno negative test

{not-applicable}: collector requirement (use FlowSet Length to find the next FlowSet); ze does not collect v9

RFC3954-x-6Finally, note that the Collector MUST accept padding in the Data FlowSet and Options Template FlowSet, which means for the Flow Data Records, the Options Data Records and the Template Records. (§9)
MUST 9
positiveno testno positive test
negativeno testno negative test

{not-applicable}: collector requirement (accept padding); ze does not collect v9 (its exporter does emit 4-octet padding at internal/plugins/flowexport/netflow9/data.go:38-44)

RFC3954-x-7If a Collector should receive a new definition for an already existing Template ID, it MUST discard the previous template definition and use the new one. (§7)
MUST 7
positiveno testno positive test
negativeno testno negative test

{not-applicable}: collector requirement (override a template on redefinition); ze does not collect v9

RFC3954-x-8Incremental sequence counter of all Export Packets sent from the current Observation Domain by the Exporter. This value MUST be cumulative (§5.1)
MUST 5.1
RFC3954-x-9The Template IDs must remain constant for the life of the NetFlow process on the Exporter. (§7)
MUST 7
positiveunit/verifyTestNetflow9FlowTemplate
positiveunit/verifyTestNetflow9Template
negativeno testno negative test

{single-polarity}: ze's NetFlow v9 template IDs are compile-time constants (CounterTemplateID=256 in internal/plugins/flowexport/netflow9/template.go, FlowTemplateID=257 and FlowTemplateID6=258 in flow_template.go) that are never reassigned for the life of the process, so there is no ID-change code path to test negatively

RFC3954-x-10The Exporter SHOULD insert some padding bytes so that the subsequent FlowSet starts at a 4-byte aligned boundary. It is important to note that the Length field includes the padding bytes. Padding SHOULD be using zeros. (§5.3)
SHOULD 5.3
positiveno testno positive test
negativeno testno negative test
RFC3954-x-11In the event of configuration changes, the Exporter SHOULD send the new template definitions at an accelerated rate. In such a case, it MAY transmit the changed Template Record(s) and Options Template Record(s), without any data, in advance to help ensure that the Collector will have the correct template information before receiving the first data. 3. On a regular basis, the Exporter MUST send all the Template Records and Options Template Records to refresh the Collector. Template IDs have a limited lifetime at the Collector and MUST be periodically refreshed. Two approaches are taken to make sure that Templates get refreshed at the Collector: * Every N number of Export Packets. * On a time basis, so every N number of minutes. Both options MUST be configurable by the user on the Exporter. When one of these expiry conditions is met, the Exporter MUST send the Template FlowSet and Options Template. 4. In the event of a clock configuration change on the Exporter, the Exporter SHOULD send the template definitions at an accelerated rate. (§7)
SHOULD 7
positiveno testno positive test
negativeno testno negative test
RFC3954-x-12NetFlow Collectors SHOULD use the combination of the source IP address and the Source ID field to separate different export streams originating from the same Exporter. (§5.1)
SHOULD 5.1
positiveno testno positive test
negativeno testno negative test
RFC3954-x-13If the Template Records have not been received at the time Flow Data Records (or Options Data Records) are received, the Collector SHOULD store the Flow Data Records (or Options Data Records) and decode them after the Template Records are received. (§9)
SHOULD 9
positiveno testno positive test
negativeno testno negative test
RFC3954-x-14This value MUST be cumulative, and SHOULD be used by the Collector to identify whether any Export Packets have been missed. (§5.1)
SHOULD 5.1
positiveno testno positive test
negativeno testno negative test
RFC3954-x-15If the template configuration is changed, the current Template ID is abandoned and SHOULD NOT be reused until the NetFlow process or Exporter restarts. (§7)
SHOULD NOT 7
positiveno testno positive test
negativeno testno negative test
RFC3954-x-16UDP [RFC768] is a non congestion-aware protocol, so when deploying NetFlow version 9 in a congestion-sensitive environment, make the connection between Exporter and NetFlow Collector through a dedicated link. This ensures that any burstiness in the NetFlow traffic affects only this dedicated link. When the NetFlow Collector can not be placed within a one-hop distance from the Exporter or when the export path from the Exporter to the NetFlow Collector can not be exclusively used for the NetFlow Export Packets, the export path should be designed so that it can always sustain the maximum burstiness of NetFlow traffic from the Exporter. (§3.3)
SHOULD 3.3
positiveno testno positive test
negativeno testno negative test
RFC3954-x-17It MAY transmit the Template FlowSet and Options Template FlowSet, without any Data FlowSets, in advance to help ensure that the Collector will have the correct Template Record before receiving the first Flow or Options Data Record. (§7)
MAY 7
positiveno testno positive test
negativeno testno negative test
RFC3954-x-18If the Exporter experiences internal constraints, a Flow MAY be forced to expire prematurely; for example, counters wrapping or low memory. (§3.2)
MAY 3.2
positiveno testno positive test
negativeno testno negative test
RFC3954-x-19Because an individual Template FlowSet MAY contain multiple Template Records (§5.2)
MAY 5.2
positiveno testno positive test
negativeno testno negative test
RFC3954-x-20Flow Data records that correspond to a Template Record MAY appear in the same and/or subsequent Export Packets. (§7)
MAY 7
positiveno testno positive test
negativeno testno negative test
RFC3954-x-21The following value fields are reserved for proprietary field types: 25, 26, 43 to 45, 51 to 54, and 65 to 69. (§8)
MAY 8
positiveno testno positive test
negativeno testno negative test
RFC3954-x-22As such, the NetFlow Collector MUST store the Template Record to interpret the corresponding Flow Data Records that are received in subsequent data packets. (§7)
MUST 7
positiveno testno positive test
negativeno testno negative test

{not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet

RFC3954-x-23A NetFlow Collector that receives Export Packets from several Observation Domains from the same Exporter MUST be aware that the uniqueness of the Template ID is not guaranteed across Observation Domains. (§7)
MUST 7
positiveno testno positive test
negativeno testno negative test

{not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet

RFC3954-x-24A Collector device MUST NOT assume that the Data FlowSet and the associated Template FlowSet (or Options Template FlowSet) are exported in the same Export Packet. (§9)
MUST NOT 9
positiveno testno positive test
negativeno testno negative test

{not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet

RFC3954-x-25The Collector MUST NOT assume that one and only one Template FlowSet is present in an Export Packet. (§9)
MUST NOT 9
positiveno testno positive test
negativeno testno negative test

{not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet

RFC3954-x-26The Collector MUST NOT attempt to decode the Flow or Options Data Records with an expired Template. (§9)
MUST NOT 9
positiveno testno positive test
negativeno testno negative test

{not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet

Gaps and untested MUSTs

RequirementStateReason
RFC3954-x-2 On a regular basis, the Exporter MUST send all the Template Records and Options Template Records to refresh the Collector. Template IDs have a limited lifetime at the Collector and MUST be periodically refreshed. Two approaches are taken to make sure that Templates get refreshed at the Collector: * Every N number of Export Packets. * On a time basis, so every N number of minutes. Both options MUST be configurable by the user on the Exporter. (§7) {gap}, no test ze refreshes NetFlow v9 templates on a time interval only (internal/plugins/flowexport/exporter.go:192-199, config template-refresh seconds); it has no packet-count-based template-refresh interval, so the conjoined time-and-packet-count refresh requirement is only partly met
RFC3954-x-4 The Collector MUST use the FlowSet ID to find the corresponding Template Record and decode the Flow Records from the FlowSet. (§5.3) no test no test carries this requirement id; annotated {not-applicable}: this is a NetFlow v9 collector requirement (map a Data FlowSet ID to its template); ze is a v9 exporter only (internal/plugins/flowexport/netflow9) with no v9 decode/collect code path
RFC3954-x-5 Because an individual Template FlowSet MAY contain multiple Template Records, the Length value MUST be used to determine the position of the next FlowSet record, which could be any type of FlowSet. (§5.2) no test no test carries this requirement id; annotated {not-applicable}: collector requirement (use FlowSet Length to find the next FlowSet); ze does not collect v9
RFC3954-x-6 Finally, note that the Collector MUST accept padding in the Data FlowSet and Options Template FlowSet, which means for the Flow Data Records, the Options Data Records and the Template Records. (§9) no test no test carries this requirement id; annotated {not-applicable}: collector requirement (accept padding); ze does not collect v9 (its exporter does emit 4-octet padding at internal/plugins/flowexport/netflow9/data.go:38-44)
RFC3954-x-7 If a Collector should receive a new definition for an already existing Template ID, it MUST discard the previous template definition and use the new one. (§7) no test no test carries this requirement id; annotated {not-applicable}: collector requirement (override a template on redefinition); ze does not collect v9
RFC3954-x-22 As such, the NetFlow Collector MUST store the Template Record to interpret the corresponding Flow Data Records that are received in subsequent data packets. (§7) no test no test carries this requirement id; annotated {not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet
RFC3954-x-23 A NetFlow Collector that receives Export Packets from several Observation Domains from the same Exporter MUST be aware that the uniqueness of the Template ID is not guaranteed across Observation Domains. (§7) no test no test carries this requirement id; annotated {not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet
RFC3954-x-24 A Collector device MUST NOT assume that the Data FlowSet and the associated Template FlowSet (or Options Template FlowSet) are exported in the same Export Packet. (§9) no test no test carries this requirement id; annotated {not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet
RFC3954-x-25 The Collector MUST NOT assume that one and only one Template FlowSet is present in an Export Packet. (§9) no test no test carries this requirement id; annotated {not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet
RFC3954-x-26 The Collector MUST NOT attempt to decode the Flow or Options Data Records with an expired Template. (§9) no test no test carries this requirement id; annotated {not-applicable}: a NetFlow v9 Collector obligation, and ze fills only the Exporter role; internal/plugins/flowexport/sender.go::NewSender dials one connected UDP socket towards the collector, and the flowexport plugin opens no listening socket and decodes no v9 Export Packet

Proof state

A tagged unit reads unproven where no discrimination record exists for it: nothing in this tree has been observed to break it, so the claim its tag makes is unproven.

RFC3954-x-1

After a NetFlow process restarts, the Exporter MUST NOT send any Data FlowSet without sending the corresponding Template FlowSet and the required Options Template FlowSet in a previous packet or including it in the same Export Packet. (§7)

Audit verdict: enforced (the tests do what the requirement demands), fresh. Both halves now proven. Exporter ordering: TestExporterTemplateFailureRetriesBeforeData (counter and flow subtests) goes red if data leaves after a failed Template or the retry transcript is not template-then-data (recorded, notifySnapshot). Corresponding Template: TestRFC3954RestartedEncodersSendTemplateBeforeData drives fresh real CounterEncoder and FlowEncoder and requires every Data FlowSet 256/257/258 to follow a packet whose Template FlowSet defines that ID, and each ID to be seen, so an encoder omitting 258 goes red (recorded, EncodeFlowTemplate). TestRFC3954TemplateFlowSetPrecedesItsDataInOnePacket pins same-packet order (recorded). The Options Template clause is vacuous: Ze emits no Options Data. TestWriteExportPacketWithTemplate stays a count-only floor and carries no record.

PolarityTestKind and tierProof state
negative TestExporterTemplateFailureRetriesBeforeData unit/verify revert, verified
positive TestWriteExportPacketWithTemplate unit/verify revert, verified
positive TestRFC3954RestartedEncodersSendTemplateBeforeData unit/verify revert, verified
positive TestRFC3954TemplateFlowSetPrecedesItsDataInOnePacket unit/verify revert, verified

RFC3954-x-2

On a regular basis, the Exporter MUST send all the Template Records and Options Template Records to refresh the Collector. Template IDs have a limited lifetime at the Collector and MUST be periodically refreshed. Two approaches are taken to make sure that Templates get refreshed at the Collector: * Every N number of Export Packets. * On a time basis, so every N number of minutes. Both options MUST be configurable by the user on the Exporter. (§7)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-2, so no unit is bound to it.

RFC3954-x-3

The Exporter MUST code all binary integers of the Packet Header and the different FlowSets in network byte order (also known as the big-endian byte ordering). (§4)

Audit verdict: enforced (the tests do what the requirement demands), fresh. Single-polarity row, every writer now compared byte for byte with distinct-octet values: Packet Header (TestNetflow9Header), counter Data FlowSet (TestNetflow9DataFlowSet), counter Template (TestRFC3954CounterTemplateFlowSetBigEndian), IPv4 and IPv6 flow Templates, IPv4 flow Data FlowSet, the shared tail with non-zero SRC_AS, DST_AS, FIRST_SWITCHED, LAST_SWITCHED (TestRFC3954FlowTailBigEndian), and the IPv6 Data FlowSet header and tail. A little-endian write of any field changes compared bytes. Every unit recorded.

PolarityTestKind and tierProof state
positive TestRFC3954CounterTemplateFlowSetBigEndian unit/verify revert, verified
positive TestRFC3954FlowTailBigEndian unit/verify revert, verified
positive TestRFC3954IPv6FlowDataFlowSetBigEndian unit/verify revert, verified
positive TestRFC3954IPv6TemplateFlowSetBigEndian unit/verify revert, verified
positive TestNetflow9DataFlowSet unit/verify revert, verified
positive TestNetflow9Header unit/verify revert, verified
positive TestRFC3954FlowDataFlowSetBigEndian unit/verify revert, verified
positive TestRFC3954TemplateFlowSetBigEndian unit/verify revert, verified

RFC3954-x-4

The Collector MUST use the FlowSet ID to find the corresponding Template Record and decode the Flow Records from the FlowSet. (§5.3)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-4, so no unit is bound to it.

RFC3954-x-5

Because an individual Template FlowSet MAY contain multiple Template Records, the Length value MUST be used to determine the position of the next FlowSet record, which could be any type of FlowSet. (§5.2)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-5, so no unit is bound to it.

RFC3954-x-6

Finally, note that the Collector MUST accept padding in the Data FlowSet and Options Template FlowSet, which means for the Flow Data Records, the Options Data Records and the Template Records. (§9)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-6, so no unit is bound to it.

RFC3954-x-7

If a Collector should receive a new definition for an already existing Template ID, it MUST discard the previous template definition and use the new one. (§7)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-7, so no unit is bound to it.

RFC3954-x-8

Incremental sequence counter of all Export Packets sent from the current Observation Domain by the Exporter. This value MUST be cumulative (§5.1)

Audit verdict: enforced (the tests do what the requirement demands), fresh. TestRFC3954SequenceCountsEveryExportPacket sends template-only, counter Data and flow Data packets from two encoders on one sender over two rounds and requires ten consecutive sequence values, so a template-only packet left out, or a per-encoder counter, goes red (recorded, sendTemplatePacket). Negative TestNetflow9SeqNumNotAdvancedOnSendError: an unsent packet does not advance the count of packets sent (recorded).

PolarityTestKind and tierProof state
negative TestNetflow9SeqNumNotAdvancedOnSendError unit/verify revert, verified
positive TestNetflow9FlowSeqNumPerPacket unit/verify revert, verified
positive TestRFC3954SequenceCountsEveryExportPacket unit/verify revert, verified

RFC3954-x-9

The Template IDs must remain constant for the life of the NetFlow process on the Exporter. (§7)

Audit verdict: enforced (the tests do what the requirement demands), fresh. Single-polarity row. TestRFC3954TemplateIDsConstantAcrossRefresh sends two full rounds and requires Templates 256, 257, 258 unchanged in round two and the Data FlowSets to name 256 and 257, so a refresh that reassigns an ID goes red (recorded, BuildFlowTemplate6). The IPv6 Template 258 is now asserted.

PolarityTestKind and tierProof state
positive TestNetflow9FlowTemplate unit/verify revert, verified
positive TestNetflow9Template unit/verify revert, verified
positive TestRFC3954TemplateIDsConstantAcrossRefresh unit/verify revert, verified

RFC3954-x-22

As such, the NetFlow Collector MUST store the Template Record to interpret the corresponding Flow Data Records that are received in subsequent data packets. (§7)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-22, so no unit is bound to it.

RFC3954-x-23

A NetFlow Collector that receives Export Packets from several Observation Domains from the same Exporter MUST be aware that the uniqueness of the Template ID is not guaranteed across Observation Domains. (§7)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-23, so no unit is bound to it.

RFC3954-x-24

A Collector device MUST NOT assume that the Data FlowSet and the associated Template FlowSet (or Options Template FlowSet) are exported in the same Export Packet. (§9)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-24, so no unit is bound to it.

RFC3954-x-25

The Collector MUST NOT assume that one and only one Template FlowSet is present in an Export Packet. (§9)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-25, so no unit is bound to it.

RFC3954-x-26

The Collector MUST NOT attempt to decode the Flow or Options Data Records with an expired Template. (§9)

Audit verdict: not audited: no reader has judged these tests

No test carries RFC3954-x-26, so no unit is bound to it.

Extraction sign-off

FieldValue
Reviewer claude
Signed off 2026-09-21
Register rfc2119
Source rfc/full/rfc3954.txt
Source fingerprint 4274d093e24b4bad
Record rfc/extraction/rfc3954.json
Mapped sentences 13
Declined as scope 6
Relocated to a spec, which Ze OWES 0
Unclassified 0

Sections

SectionNameSitesDispositionReason
front not stated 0 walked not stated
1 not stated 0 walked not stated
2 not stated 0 walked not stated
2.1 not stated 0 walked not stated
3 not stated 0 walked not stated
3.1 not stated 0 walked not stated
3.2 not stated 0 walked not stated
3.3 not stated 0 walked not stated
4 not stated 1 walked not stated
5 not stated 0 walked not stated
5.1 not stated 1 walked not stated
5.2 not stated 1 walked not stated
5.3 not stated 1 walked not stated
6 not stated 0 walked not stated
6.1 not stated 1 walked not stated
6.2 not stated 1 walked not stated
7 not stated 8 walked not stated
8 not stated 0 walked not stated
9 not stated 5 walked not stated
10 not stated 0 walked not stated
10.1 not stated 0 walked not stated
10.2 not stated 0 walked not stated
10.3 not stated 0 walked not stated
11 not stated 0 walked not stated
11.1 not stated 0 walked not stated
11.2 not stated 0 walked not stated
11.3 not stated 0 walked not stated
11.4 not stated 0 walked not stated
11.5 not stated 0 walked not stated
12 not stated 0 walked not stated
12.1 not stated 0 walked not stated
12.2 not stated 0 walked not stated
13 not stated 0 walked not stated
14 not stated 0 walked not stated
15 not stated 0 walked not stated

Excluded sentences

SiteExcluded kindReasonQuote
6.1:1 duplicate-of
never bound Ze
the same obligation is already captured under another requirement id
restates the Length-determines-next-FlowSet obligation already mapped at site 5.2:1 Thus, the Length value MUST be used to determine the position of the next FlowSet record, which could be either a Template FlowSet or Data FlowSet.
6.2:1 duplicate-of
never bound Ze
the same obligation is already captured under another requirement id
restates the FlowSet-ID-selects-the-template obligation already mapped at site 5.3:1 The Collector MUST use the FlowSet ID to map the appropriate type and length to any field values that follow.
7:6 duplicate-of
never bound Ze
the same obligation is already captured under another requirement id
restates the periodic template refresh obligation already mapped at site 7:5 Template IDs have a limited lifetime at the Collector and MUST be periodically refreshed.
7:7 duplicate-of
never bound Ze
the same obligation is already captured under another requirement id
the configurability of the two refresh intervals is part of the same refresh obligation mapped at site 7:5 Both options MUST be configurable by the user on the Exporter.
7:8 duplicate-of
never bound Ze
the same obligation is already captured under another requirement id
restates the send-on-expiry half of the refresh obligation already mapped at site 7:5 When one of these expiry conditions is met, the Exporter MUST send the Template FlowSet and Options Template.
9:4 duplicate-of
never bound Ze
the same obligation is already captured under another requirement id
restates the override-on-redefinition obligation already mapped at site 7:3 If the Collector receives a new Template Record (for example, in the case of an Exporter restart) it MUST immediately override the existing Template Record.

Superseded

No document obsoletes RFC 3954, so its obligations are stated where they were written.